H – Henry.
H-20 – Also referred to as “HS20-44” or “H20-44” Bridge Loading. H20 Loading refers to a maximum front wheel loading of 8000 lbs and a maximum rear wheel load of 16,000 lbs with an impact factor of 30% added (16000 x 1.30) for a total maximum wheel loading of 20,000 lbs.
H2 – Hydrogen.
H20-44 – See “H20”.
Half-duplex communications – A communications system in which data can travel in both directions, but only in one direction at a time.
Hard Drawn – Wire that has been drawn to its specific size and not annealed.
Hard Line – A Steel Pulling line. Also see Bull Line.
Harmonic – A sinusoidal component of the voltage that is a multiple of the fundamental wave frequency.
Harmonic Distortion – The presence of harmonics that change an AC waveform from sinusoidal to complex. They can cause unacceptable disturbance to electronic equipment.
Hazard Risk Category – Categories defined by NFPA 70E-2004 to explain protection levels needed when performing tasks. The values range from 1 to 4. ATPV rated PPE is required for categories 1 through 4 as follows: 1- 4 cal/cm²; 2- 8 cal/cm²; 3- 25 cal/cm²; 4- 40 cal/cm².
Heat Run Test – A test that is used to determine the increase in operating temperature at a given load.
Helical – Wrapped in a spiral fashion. Refers to the way the strands of a conductor are laid.
Henry – The meter-kilogram-second unit of inductance, equal to the inductance of a circuit in which an electromotive force of one volt is produced by a current in the circuit which varies at the rate of one ampere per second.
Hertz – 1) A unit of frequency equal to one cycle per second. 2) In alternating current, the changing of the negative and positive poles.
HID – High Intensity Discharge.
High Intensity Discharge (HID) Lamp – An electric discharge lamp in which the light producing arc is stabilized. Examples of HID lamps include High Pressure Sodium, Metal Halide and Mercury Vapor.
High Pot – A test done to confirm the reliability of an insulation system where a high voltage is applied.
High Pressure Sodium (HPS) Lamp – A High Intensity Discharge light source in which the arc tube’s primary internal element is Sodium Vapor.
High Voltage – An electrical system or cable designed to operate between 46kv and 230kv.
High Voltage System – An electric power system having a maximum roo-mean-square ac voltage above 72.5 kilovolts (kv).
High-speed reclosing – A re-closing scheme where re-closure is carried out without any time delay other than required for deionization.
Hooks – See “Climbers”.
Hookstick – An insulated stick, usually made of fiberglass, that is used to work energized overhead conductors and operate electrical equipment.
Horsepower – A unit of work. When used to show power usage, one horsepower is equivalent to 746 watts.
Hose – Slang for “Line Hose”.
Hot – Refers to an energized conductor or apparatus.
Hot Arm – A device that is used to temporarily extend a conductor beyond the cross arm it was on.
Hotstick – An insulated stick, usually made of fiberglass, that is used to work energized overhead conductors and operate electrical equipment that is overhead, underground and pad mounted.
HPS – High Pressure Sodium.
HRC – High Rupturing Capacity (applicable to fuses).
HS20-44 – See “H-20”
HS285 (TM) – Aluminum Conductor, Steel Supported with Extra High Strength Steel Core. HS285 is a Trademark of Southwire Company.
HSR – High Speed Re-closing.
HV – High Voltage.
Hybrid Photovoltaic System – A photovoltaic system that includes other sources of electric generation such as wind or fossil fuel.
Hydrometer – A float type instrument used to determine the state-of-charge of a battery by measuring the specific gravity of the battery electrolyte (i.e., the amount of sulfuric acid in the electrolyte).

 


Would you like a complimentary…no obligation …project consultation? Please feel free to call for more details.

Goodiel Electric LLCFor A Great Deal Call Goodiel Electric – Electrician.
Glenn Goodiel.
Mobile: 772-263-2333.
Florida License – EC13005097.

For a Great deal, call electrician and Martin County electrical contractor Glenn Goodiel.

In Martin County, Goodiel Electric, LLC. services Hobe Sound, Indiantown, Jensen Beach, Jupiter Island, North River Shores, Ocean Breeze Park, Palm City, Port Salerno, Rio, Sewalls Point and Stuart.

In St. Lucie County, Goodiel Electric, LLC. services Port St. Lucie, St. Lucie West, Tradition, Torino, Tesoro, Lake Charles, Lake Forest, Magnolia Lakes, PGA Village, The Vineyards, St James Golf Club, The Cascades, Fort Pierce, White City and the unincorporated areas of St. Lucie County.


Port Saint Lucie Tile Contractor.

Lake Charles Floor Tile Contractor – Boyer Tile LLCBoyer Tile LLC.

Chris Boyer.
Port St. Lucie Tile Contractor – Tile Installation.

Call via Home Phone:  (772) 626-1403.
Mobile: (772) 626-1403.
Skype: (772) 626-1403.

 

Quality Work is My Trademark.

Master Tile Setter and St. Lucie West Bathroom Flooring Contractor.